Analysis of load distribution in multi-storey shear wall structures

Por: Colaborador(es): Analíticas: Mostrar analíticasTipo de contenido:
  • texto
Tipo de medio:
  • sin mediación
Tipo de soporte:
  • volumen
Tema(s):
Contenidos:
A method is presented for the analysis of the distribution of load amongst the shear walls of a three-dimensional multi-storey building subjected to bending and torsion. The method is based on the continuous connection technique
En: The structural engineer (vol. 48, nro. 8, Aug. 1970), p. 301-306S.T.:H624.04 STR PP2480
Valoración
    Valoración media: 0.0 (0 votos)
No hay ítems correspondientes a este registro

A method is presented for the analysis of the distribution of load amongst the shear walls of a three-dimensional multi-storey building subjected to bending and torsion. The method is based on the continuous connection technique